ED3100-FP Series Energy-Saving Variable Frequency Drive for Fan and Pump

ED3100-FP Series Energy-Saving Variable Frequency Drive for Fan and Pump
Request a Quote
ED3100-FP Series

It is common practice to allow for some deviations from the rated capacity in design of industrial fans and pumps. Designers also add dampers or valves to regulate the flow of air or liquid into and out of the fan or pumping system. These flow control methods are simple but also wasteful. As a matter of fact, the significant usefulness of our variable frequency drive comes from the large amount of energy it saves in the pump or fan speed control system, eliminating the need for any dampers or valves.

Features of Variable Frequency Drive
1. Overload capacity: rated current×120%/min, rated current ×150%/sec
2. Smooth startup protects the fan and pump from shock load.
3. The PLC system, coupled with the bypass control, ensures the variable frequency drive can freely switch between two fixed frequencies.
4. The speed tracking control allows the drive to deliver a motor speed the same as the previous one. In this way the decelerated motor can retain its speed without experiencing shock load.
5. Automatic energy-saving features adjust the motor speed according to the varying electric loads.
6. Built-in PID functions offer both open loop and closed loop controls.
7. Various other control and protection features are available.

Applications of VFD
Our variable frequency drive can be connected to the fan in an industrial or residential boiler, mine ventilation system, cement or ceramic furnace, dust collection system, the metro station, large workshop, sports venue, and the air compressor.

The variable frequency drive also can be attached to the pump of the urban heating supply system, central air conditioning system, cooling water system, water plant, sewage treatment factory, dyeing equipment, and water supply system

VFD Installation Size

ED3100P Series specification lis
Series kw H(mm) W(mm) D(mm) H1(mm) W1(mm) R(mm) Note
power Shell Size Installation Size Aperture
ED3100P 5.5-7.5 270 226 179 256.5 210 3.25 Plastic Shell
11-18.5 350 247 232 334 186 4.5 Metal Shell
22-30 530 341 285 510 200 5.5  
37-45 600 368 281 580 230 5  
55-75 679 394 302 659 300 6  
93-132 825 533 368.6 797 420 6  
160-200 1250 684 470 1222 420 6  
160-200 1425 420 470 1411 420    
220-280 1500 700 471 cabinet Installation    
315-400 1600 830 482 cabinet Installation    

Specifications
ED3100-FP Series Variable Frequency Drive for Fan and Pump Specs
Input Rated voltage and frequency Single-phase 220V, three-phase 220V,
Three-phase 380V; 50Hz/60Hz
Allowable variations (tolerance) Voltage: -20% 20
Voltage unbalance: <3%
Frequency: ±5
Output Rated voltage 0~200V /0380V
Frequency range 0Hz~400Hz
Overload capability 150% for 1 min, 180% for 1s, 200% instant protection required
Main control function Control mode PWM modulator (using voltage vector for effective control)
Sensorless vector control (SVC)
Frequency accuracy Digital mode: Max frequency ×±0. 01%
Analog mode: Max frequency ×±0. 2%
Frequency resolution Digital mode: 0.01Hz
Analog mode: Max frequency ×0.1%
Torque rise Auto torque rise
Manual torque rise 1%~30.0%
V/F curve Linear V/F curve
Quadratic V/F curve
User-defined V/F curve
S-curve acceleration/deceleration Optional time units: Min/s
Maximum acceleration and deceleration time: 6000s (adjustable within the range of 0.1~3600s).
DC braking unit Operating frequency: 0~20Hz
Operating voltage level: 0~20%
Operating time: ± 0~20s
Jog switch Jog frequency range: 0.1Hz~50.00Hz
Jog acceleration and deceleration time: 0.1~3600s.
Built-in PID A closed loop control system is formed with the aid of built-in PID which is applicable for process control such as the adjustment of flow rate and water pressure.
Multiple preset speeds Built-in PLC system, together with control terminals, produces a number of preset speeds.
Weave and wobble Adjustable wobble frequency
Auto voltage adjustment When the mains voltage changes, the output voltage is kept constant by adjusting PWM output (AVR function).
Power saving mode V/F curve is adjustable to varying load conditions so as to maintain an optimal level of energy efficiency all the time.
Auto current control Current-limiting features prevent the VFD control tripping on a fault caused by excess current.
Sensorless vector control Torque 150% torque output at 1Hz
Torque adjustment accuracy: 0.1%
Automatic display of motor parameters Check parameters on the display when the motor completely stops in order to achieve optimal control
Run Enable Command channels for variable frequency drive Selection of operation modes
Setting of control terminals
Setting of serial ports