Fire resistant cables are necessary in environments with high energy demands and high safety requirements such as high-rises, power stations, mines, and subways. These flame resistant cables are especially important for emergency power lines, fire-control systems, and communication systems. In case there is a fire, the flame retardant cables will still be able to function properly to ensure that no vital systems are lost.

Thank you for your interest in Leshan Cable, a professional Chinese electrical cable provider. If you have any product-related questions, please feel free to call.

Reference standard: As per the enterprise standard

The flame resistant cable chooses type and usage
Announcements

1. NH flame resistant cables should be selected for normal requirements. DDNH low smoke, low halogen or WDNH low smoke non-halogen is for places with restricted environmental requirements.
2. The diameter of flame-resistant cable is 15%~25% larger than that of an ordinary cable.
3. The user should strictly avoid damaging the cable with sharp objects or over-bending it. This may affect the fire-resistance of the cable.
4. Four layers of mica tape should be wrapped between the insulation and conductor to act as the fire-resistant layer in the connection of the cable.

Type Description
NH-VV Flame-resistant power cable with Cu core PVC insulation & sheath
NH-VV22 Flame-resistant power cable with Cu core PVC insulation & sheath, steel tape armor
NH-YJV Flame-resistant power cable with Cu core XLPE insulation, PVC sheath.
NH-YJV22 Flame-resistant power cable with Cu core XLPE insulation PVC sheath, steel tape armor
NH-KVV Flame-resistant control cable with Cu core PVC insulation & sheath
NH-KVV22 Flame-resistant control cable with Cu core PVC insulation & sheath, steel tape armor
NH-KYJV Flame-resistant control cable with Cu core XLPE insulation PVC sheath
NH-KYJV22 Flame-resistant control cable with Cu core XLPE insulation PVC sheath, steel tape armor
NH-BV Flame-resistant power cable(wire) with Cu core PVC insulation
NH-BVV Flame-resistant power cable(wire) with Cu core PVC insulation & sheath
NH-RVV Flame-resistant power soft cable with Cu core PVC insulation & sheath
Type U0/U(V) Core number Area (mm2)
NH-VV , NH-VV22
NH-YJV , NH-YJV22
600/1000 1 2.5~300
2 core , 3/4 core , 3 1 core , 3 2 core 2.5~240
NH-KVV , NH-KVV22
NH-KYJV , NH-KYJV22
450/750 2~61 core 2.5~10
NH-BV 450/750 1 1.5~300
NH-BVV 1~5
NH-RVV 600/100 1 1.5~300
2~5 10~240
Standard Flame temperature(°C) firing time additional voltage(V) additional current Experiment result
IEC331 750 3h Rated voltage 3A Have no the power failure
GB12666.6 A type 950-1000 90min Rated voltage 3A
B type 750-800 90min Rated voltage 3A