PVC Insulated Cable

PVC Insulated Cable
PVC Insulated Cable
Request a Quote

This cable product is used for the distribution of AC electricity with rated voltage below 450/750V. PVC insulated cable consists of multiple conductors insulated with a coating of PVC. This is different from a wire as that is a single insulated conductor.

Leshan is an expert in Chinese power cable industry. We have been supplying customers from around the globe with quality insulated cables for decades.

The PVC insulated cable is built to the standard
GB/T5023-2008 PVC insulated wires with voltages no higher than 450/750V
JB/T PVC insulated wires with voltages no higher than 450/750V

Characteristic of use
The maximum working temperature of the wire conductor is between 70℃ and 90℃.

Type Description Core number Area (mm2) Voltages (V) Standard
227IEC01 (BV) Single-core hard drawn non-sheathed cable 1 1.5~400 450/750 GB5023.3
227IEC02 (RV) Single-core soft drawn non-sheathed cable 1 1.5~240 450/750
227IEC05 (BV) Single-core solid conductor drawn non sheathed cable for internal wiring is 70°C 1 0.5~1.0 300/500
227IEC06 (RV) Single-core soft drawn non sheathed cable for internal wiring is70°C 1 0.5~1.0 300/500
227IEC07 (BV-90) Single-core solid conductor drawn non sheathed cable for internal wiring is 90°C 1 0.5~2.5 300/500
227IEC08 (RV-90) Single-core soft drawn non sheathed cable for internal wiring is 90°C 1 0.5~2.5 300/500 GB5023.3
227IEC10 (BVV) Light PVC sheathed cable 2~5 1.5~35 300/500 GB5023.4
227IEC52 (RVV) Light PVC sheathed soft wires 2, 3 0.5/0.75 300/300 GB5023.5
227IEC53 (RVV) Ordinary PVC sheathed soft wires 2~5 0.75~2.5 300/500
BV Cu-core PVC insulated wires 1 0.75/1.0 300/500 JB8734.2
BLV Al-core PVC insulated wires 1 2.5~400 450/750
BVR Cu-core PVC insulated soft wires 1 2.5~70 450/750
BVV Cu-core PVC insulated and sheathed circle type wires 1 0.75~10 300/500 JB8734.2
BLVV Al-core PVC insulated and sheathed circle type cable 1 2.5~10 300/500
BVVB Cu-core PVC insulated and sheathed Flat type cable 2, 3 0.75~10 300/500
BLVVB Al-core PVC insulated and sheathed Flat type cable 2, 3 2.5~10 300/500
RVVP Cu-core PVC insulated and sheathed the Metallic shielded soft cable 1~24 0.08~2.5 300/500 JB8734.5
Rated cross area(mm2) 0.5 0.75 1 1.5 2.5 4 6 10
Cu Non tinned 36 24.5 18.1 12.1 7.41 4.61 3.08 1.83
(Ω/km) Tinned 36.7 24.8 18.2 12.2 7.56 4.7 3.11 1.84
Al(Ω/km) / / / 18.1 12.1 7.41 4.61 3.08
Rated cross area(mm2) 16 25 35 50 70 95 120 150
Cu (Ω/km) Non tinned 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124
Tinned 1.16 0.734 0.529 0.391 0.27 0.195 0.154 0.126
Al (Ω/km) 1.91 1.2 0.868 0.641 0.443 0.32 0.253 0.206
Rated cross area(mm2) 185 240 300 400 500 630 800 1000
Cu (Ω/km) Non tinned 0.0991 0.0754 0.0601 0.047 0.0366 0.0283 0.0221 0.0176
Tinned 0.1 0.0762 0.0607 0.0475 0.0369 0.0286 0.0224 0.0177
Al(Ω/km) 0.164 0.125 0.1 0.0778 0.0605 0.0469 0.0367 0.0291
Nominal Area(mm2) 0.5 0.75 1 1.5 2.5 4 6
silk biggest diameter(mm) 0.21 0.21 0.21 0.26 0.26 0.31 0.31
resistances No tin-plated 39 26 19.5 13.3 7.98 4.95 3.3
(Ω/km) Tin- plated 40.1 26.7 20 13.7 8.21 5.09 3.39
Nominal Area(mm2) 10 16 25 35 50 70 95
silk biggest diameter(mm) 0.41 0.41 0.41 0.41 0.41 0.51 0.51
resistances No tin-plated 1.91 1.21 0.78 0.554 0.386 0.272 0.206
(Ω/km) Tin- plated 1.95 1.24 0.795 0.565 0.393 0.277 0.21
Nominal Area(mm2) 120 150 185 240 300 400 500
silk biggest diameter(mm) 0.51 0.51 0.51 0.51 0.51 0.51 0.61
resistances No tin-plated 0.161 0.129 0.106 0.0801 0.0641 0.0495 0.0391
(Ω/km) Tin- plated 0.164 0.132 0.108 0.0817 0.0654 0.0495 0.0391
TableA-1: The current-carrying capacity is on 750V or lower PVC insulate power wire(cable)
Applythe model number: BV BLV BVV BLVV
Limit the term : Environment temperature 25°C at air
Area (mm2) 2-core 3-core 4-core
Cu Al Cu Al Cu Al
1.0 12 / 11 / 10 /
1.5 16 / 15 / 13 /
2.5 24 18 21 16 19 14
4 31 24 28 22 25 19
6 41 31 36 27 32 25
10 56 42 49 38 44 33
16 72 55 65 49 57 44
25 95 73 85 65 75 57
35 120 90 105 80 93 70
50 150 114 132 102 117 90
70 185 145 167 130 148 115
95 230 175 205 158 185 140
120 270 200 240 180 215 160
150 305 230 275 207 250 185
185 355 265 310 235 280 212
Nominal Area (mm2) Conductor category Insulate thickness (mm) Biggest Diameter (mm) 70°C Least insulates resistance MΩ·km
1.5 1 0.7 3.3 0.011
2 0.7 3.4 0.010
2.5 1 0.8 3.9 0.010
2 0.8 4.2 0.009
4 1 0.8 4.4 0.0085
2 0.8 4.8 0.0077
6 1 0.8 4.9 0.0070
2 0.8 5.4 0.0065
10 1 1.0 6.4 0.0070
2 1.0 6.8 0.0065
16 2 1.0 8.0 0.0050
25 2 1.2 9.8 0.0050
35 2 1.2 11.0 0.0040
50 2 1.4 13.0 0.0045
70 2 1.4 15.0 0.0035
95 2 1.6 17.0 0.0035
120 2 1.6 19.0 0.0032
150 2 1.8 21.0 0.0032
185 2 2.0 23.5 0.0032
240 2 2.2 26.5 0.0032
300 2 2.4 29.5 0.0030
400 2 2.6 33.5 0.0028
Note: 1 conductor is a solid conductor, 2 conductors wring to match the conductor formany root. The bottom is together, below too such.
Nominal Area (mm2) Insulate thickness (mm) Biggest Diameter (mm) 70°C Least insulates resistance MΩ·km
1.5 0.7 3.5 0.010
2.5 0.8 4.2 0.009
4 0.8 4.8 0.007
6 0.8 6.3 0.006
10 1.0 7.6 0.0056
16 1.0 8.8 0.0046
25 1.2 11.0 0.0044
35 1.2 12.5 0.0038
50 1.4 14.5 0.0037
70 1.4 17.0 0.0032
95 1.6 19.0 0.0032
120 1.6 21.0 0.0029
150 1.8 23.5 0.0029
185 2.0 26.0 0.0029
240 2.2 29.5 0.0028
Nominal Area (mm2) Insulate thickness (mm) Biggest Diameter (mm) 70°C Least insulates resistance MΩ·km
0.5 0.6 2.4 0.015
0.75 0.6 2.6 0.012
1.0 0.6 2.8 0.011
Nominal Area (mm2) Insulate thickness (mm) Biggest Diameter (mm) 70°C Least insulates resistance MΩ·km
0.5 0.6 2.6 0.013
0.75 0.6 2.8 0.011
1.0 0.6 3.0 0.010
Nominal Area (mm2) Insulate thickness (mm) Biggest Diameter (mm) 90°C Least insulates resistance MΩ·km
0.5 0.6 2.4 0.015
0.75 0.6 2.6 0.013
1.0 0.6 2.8 0.012
1.5 0.7 3.3 0.011
2.5 0.8 3.9 0.009
Nominal Area (mm2) Insulate thickness (mm) Biggest Diameter (mm) 90°C Least insulates resistance MΩ·km
0.5 0.6 2.6 0.013
0.75 0.6 2.8 0.012
1.0 0.6 3.0 0.010
1.5 0.7 3.5 0.009
2.5 0.8 4.2 0.009
Nominal Area (mm2) Single line number of conductor Insulate thickness (mm) Biggest Diameter (mm) 70°C Least insulates resistance MΩ·km
0.75 7 0.6 2.6 0.014
1.0 7 0.6 2.8 0.013
Nominal Area (mm2) Minimal number in conductor Insulate thickness (mm) Biggest Diameter (mm) 70°C Least insulates resistance MΩ·km
2.5 1 0.8 3.9 0.010
4 1 0.8 4.4 0.0085
6 1 0.8 5.0 0.0070
10 7 1.0 6.7 0.0065
16 7 1.0 7.8 0.0050
25 7 1.2 9.7 0.0050
35 7 1.2 10.9 0.0040
50 19 1.4 12.8 0.0045
70 19 1.4 14.6 0.0035
95 19 1.6 17.1 0.0035
120 37 1.6 18.8 0.0032
150 37 1.8 20.9 0.0032
185 37 2.0 23.3 0.0032
240 61 2.2 26.6 0.0032
300 61 2.4 29.6 0.0030
400 61 2.6 33.2 0.0028
Nominal Area (mm2) Minimal number in conductor mm thickness Biggest Diameter (mm) 70°C Least insulates resistance MΩ·km
Insulate sheathed
Cu Al
0.75 / 1 0.6 0.8 4.4 0.012
1.0 / 1 0.6 0.8 4.5 0.011
1.5 / 1 0.7 0.8 5.0 0.011
1.5 / 7 0.7 0.8 5.2 0.010
2.5 2.5 1 0.8 0.8 5.7 0.010
2.5 / 7 0.8 0.8 5.9 0.009
4 4 1 0.8 0.9 6.5 0.0085
4 / 7 0.8 0.9 6.8 0.0077
6 6 1 0.8 0.9 7.1 0.0070
6 / 7 0.8 0.9 7.3 0.0065
10 10 7 1.0 0.9 8.8 0.0065