Current and Voltage Calibrator
Request a Quote
Functions
1. The current and voltage calibrator can source voltage, current and frequency.
2. It supports measurement of voltage, current, loop current and frequency.
3. Manual stepping as well as automatic stepping and ramping functions are available.
4. The multifunctional process calibrator supports PC communication as well.
Functions | Measure | Source |
DC V | 0 ~ 30 V | 0 ~ 10 V |
DC mV | 0 ~ 100 mV | 0 ~ 100 mV |
DC mA | 0 ~ 24 mA | 0 ~ 24 mA |
Frequency | 1.000Hz ~ 99.999kHz | 0.00Hz ~ 20.000kHz |
Others | 24V power supply, Step, Ramp. |
Specifications of the Current and Voltage Calibrator
Specifications are based on a one year calibration cycle and apply from 18℃ to 28 ℃ unless stated otherwise. All specifications assume a 10 minute warmup period.
Range | Maximum measurement range | Resolution | Accuracy (% of reading Counts) | |
| | |||
30V | 0V ~ 31V | 0.001V | 0.05 2 | 0.02 2 |
100mV | -15mV ~ 80mV | 0.001mV | 0.05 20 | 0.02 20 |
80mV ~ 125mV | 0.01mV | 0.05 2 | 0.02 2 | |
-10 ℃ ~ 18 ℃ , 28 ℃ ~ 55 ℃ temperature coefficient, ±0.005%FS/ ℃ . Input resistance: > 1MΩ. |
Range | Maximum output span | Resolution | Accuracy (% of reading Counts) | |
| | |||
100mV | -15mV ~ 99.999mV | 0.001mV | 0.05 20 | 0.02 20 |
100mV ~ 125mV | 0.01mV | 0.05 2 | 0.02 2 | |
10V | 0 ~ 11V | 0.001V | 0.05 2 | 0.02 2 |
-10 ℃ ~ 18 ℃ , 28 ℃ ~ 55 ℃ temperature coefficient, ±0.005%FS/ ℃ . Maximum load: 1mA or 1kΩ ( It should be based on the lower load.) |
Range | Maximum measurement range | Resolution | Accuracy (% of reading Counts) | |
| | |||
20mA | 0 ~ 24mA | 0.001mA | 0.05 2 | 0.02 2 |
-10 ℃ ~ 18 ℃ , 28 ℃ ~ 55 ℃ temperature coefficient, ±0.005%FS/ ℃ . Input resistance: < 100Ω. |
Range | Maximum output range | Resolution | Accuracy (% of reading Counts) | |
| | |||
20mA | 0 ~ 24mA | 0.001mA | 0.05 2 | 0.02 2 |
20mA (Transducer simulation) | 0 ~ 24mA | 0.001mA | 0.05 2 | 0.02 2 |
-10 ℃ ~ 18 ℃ , 28 ℃ ~ 55 ℃ temperature coefficient,±0.005%FS/ ℃ . Maximum load voltage: 20V, equivalent to voltage of 20mA on 1000Ω load resistance. |
Range | Maximum measurement range | Resolution | Accuracy (% of reading Counts) | |
| | |||
100Hz | 1 ~ 99.999Hz | 0.001Hz | 0.02 1 | 0.01 1 |
1000Hz | 100 ~ 999.99Hz | 0.01Hz | ||
10kHz | 1k ~ 9.9999kHz | 0.1Hz | ||
100kHz | 10k ~ 99.999kHz | 1Hz | ||
Sensitivity: 10Hz ~ 10kHz, Vp-p≥1V; the rest :Vp -p≥2V. Wave form: 5 counting points should be added to errors of other wave forms. Commercial frequency can be measured directly. |
Range | Maximum output range | Resolution | Accuracy (% of reading Counts) | |
| | |||
200Hz | 0 ~ 200Hz | 0.01Hz | 0.02 1 | 0.01 1 |
2000Hz | 0 ~ 2000Hz | 0.1Hz | ||
20kHz | 0 ~ 20kHz | 1Hz | ||
Output amplitude: ≥4.5Vp-p ; Wave form: Square wave |