- SDY Series Junction Box For Energy Meter
- SMJL-SMJJ(Naked-Insulated Cable)insulated Joint Pipe
- SMJY(Different Diameter)Pre-insulated Joint Pipe
- SMJT(Same-diameter)Pre-insulated Joint Pipe
- Terminals Assortment
- Non-Insulated Terminal
- Non-Insulated Spade Terminal
- Insulated Spade Terminal
- Insulated Ring Terminal
- Copper Tube Terminal
- MG-METAL
- PG-METAL
- MG-NYLON
- PG-NYLON
- SF-8808
- SF-8807
- SF-8806
- SF-8805
- SF-8804
- SF-8803
- SF-CB04
- SF-CB03
- SF-CB02
- SF-CB01 (Ultra-thin Series)
- 80x80x38mm
- More
SF-8807
Parameters
| Name | Model | Sizes(outside) | Air flow | Dust Resistance rate | Damage Area | |
| Ventilator Filter Unit | SF-8807A | 420mm×180mm×13.5mm | 100.0 m3/min | 2.0M/SEC | 92% | 6.7~40 INCH- H2O |
| Cooling Fan Unit | SF-8807C(A)-1(2) | 8.4m3/min | ||||
| SF-8807C(B)-1(2) | 11.6 m3/min |
| Name | Usage area | Material | Weight | Protection Class |
| Ventilator Filter Unit | Indoors -10℃~+55℃ | ABC resin inflammable UV-resistance Fire protection classification | 518g | IP54 |
| Cooling Fan Unit | Franic(aluminum alloy)&fan leaf(construction plastic) | 218g | ||
| 2450g |
As a specialized ventilator filter unit manufacturer and supplier, located in China, we have successfully obtained ISO9001:2000 certification. Our products, like screw clamp terminal block, steel din rail, complex suspension insulator, etc. are CE certified and well received by customers from Southeast Asia, Europe and South America.
If you have any related need, please feel free to contact us at SMS.

- SF-8806
- Ventilator Filter Unit, SF-8806 Parameters Name Model Sizes(outside) Air flow Dust Resistance rate Damage Area Ventilator Filter Unit SF-8806A 320mm×320mm×13.5mm 120.0 m 3 /min 2.0M/SEC 92% 6.7~40 INCH- H2O Cooling Fan Unit SF-8806C-1(2) 16.0m 3 /min

- SF-8805
- Ventilator Filter Unit, SF-8805 Parameters Name Model Sizes(outside) Air flow Dust Resistance rate Damage Area Ventilator Filter Unit SF-8805A 255mm×255mm×13.5mm 80.0 m 3 /min 2.0M/SEC 92% 6.7~40 INCH- H2O Cooling Fan Unit SF-8805C-1(2) 10.2m 3 /min

- SF-8804
- Ventilator Filter Unit, SF-8804 Parameters Name Model Sizes(outside) Air flow Dust Resistance rate Damage Area Ventilator Filter Unit SF-8804A 204mm×204mm×13.5mm 50.0 m 3 /min 2.0M/SEC 92% 6.7~40 INCH- H2O Cooling Fan Unit SF-8804C-1(2) 50.0m 3 /min

- SF-8803
- Ventilator Filter Unit, SF-8803 Parameters Name Model Sizes(outside) Air flow Dust Resistance rate Damage Area Ventilator Filter Unit SF-8803A 148.5mm×148.5mm×13.5mm 25.0 m 3 /min 2.0M/SEC 92% 6.7~40 INCH- H2O Cooling Fan Unit SF-8803C-1(2) 25.0m 3 /min