XLPE Insulated Power Cable

XLPE Insulated Power Cable

XLPE Insulated Power Cable

XLPE insulated power cable
is used to transmit and distribute power for the power transmission and distribution system of 35kV or lower. It is generally applied in the fields of power,construction,mine,metallurgy, petrochemical industry and communication. It completely replaces the oil immersed paper insulated power cable andpartiallyreplaces the PVC insulated power cable.

Type

Name

Main Application

Cu core

Al core

YJV
YJY

YJLV
YJLV

XLPE insulated, PVC or PE Sheathed Power Cable

For laying indoor, tunnel, channel and underground. Unable to bear external mechanical force, but bear the traction force during laid

YJV22
YJV22

YJLV22
YJV22

XLPE Insulated, Steel Tape Armored, PVC or PE Sheathed Power Cable

For laying indoor, tunnel, channel and underground. Able to bear external mechanical force, but unable to bear large pulling force

YJV32
YJV32

YJLV32
YJLV32

XLPE Insulated, Fine Steel Wire Armored, PVC or PE Sheathed Power Cable

For laying in shaft with large difference of level. Able to bear external mechanical force and moderate pulling force

YJV42
YJV42

YJLV42
YJLV42

XLPE Insulated, Thick Steel Wire Armored, PVC or PE Sheathed Power Cable

Able to bear positive pressure and pulling force

Note:"ZR-" includes ABC three kinds of flame retardent cables,which are respectively indicated in "ZRA-" or "ZRB-" "ZRC-".For example:"ZRB-YJV", "ZRA-YJV22".

Rated Voltage,No. of Core and Range of Sectional Area

Rated voltage (kv)

Sectional area (mm2)

No. of core

1st class

0.6/1

1.8/3

3.6/6

6/10

8.7/15

12/20

18/30

21/35

2nd class

1/1

3/3

6/6

8.7/10

12/15

18/20

-

26/35

1 Core

1.5-800

25-800

25-1200

25-1200

35-1200

50-1200

50-1200

50-1200

2 Core

1.5-185

25-185

3 Core

1.5-400

25-400

25-400

25-400

35-400

50-400

50-400

50-400

4 Core

2.5-400

25-400

5 Core

2.5-400

25-400


Main Technical Quota

1
. DC resistance:conductor resistance of finished cable at 20 per kilometer is not more than the following values.

Nominal section area (mm2)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

Copper core

12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221

Aluminum core

18.1 12.1 7.41 4.61 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.778 0.0605 0.0469 0.0367


2. Voltage Test and Partial Discharge Test

Rate voltage Uo (kv)

Item

0.6/1

1.8/3

3.6/6

6/6
6/10

8.7/10
8.7/15

12/20

18/20
18/30

21/35

26/35

Voltage

Test voltage

3.5

6.5

12.5

21

30.5

42

63

73.5

91

Test time

5

5

5

5

5

5

5

5

5

Partial discharge test

Test voltage

-

-

6.2

10.4

15.1

20.8

31.1

36.3

45

Discharge capacity

-

-

10

10

10

10

10

10

10


Construction from the Inner Part to the Exterior Part of the XLPE Insulated Power Cable
Copper or aluminum conductor

XLPE insulation

Copper tape or copper wire screen

Galvanized steel wire or tape armored

PVC or PE sheath

Package

The insulated power cable comesindrums or coils.

Tong-Da is an experienced XLPE insulated power cable manufacturer and supplier in China. In order to satisfy customers' various demands, we also provide PVC insulated wire, galvanized steel wire, galvanized steel strand, PVC insulated power cable, all aluminium conductor, ACSR, etc.

Feedback Form