BN-200 Infant Radiant Warmer

BN-200 Infant Radiant Warmer
Request a Quote
BN-200

The BN-200 infant radiant warmer with ultra-large nursing table is highlighted by inviting fashion and elegance. It enables the display of skin, bed and room temperature, and the angle and luminance of light are adjustable to better facilitate clinical care. The height of entire product can be adjusted as well. We also configure it with an X-ray cassette tray, a drawer for item storage and a nursing tray. In addition, the jaundice therapeutic apparatus and the oxygen supplying system can be optionally provided.

Functional Features
1. A touch screen control panel is equipped to this infant radiant warmer.
2. The digital skin temperature sensor features accurate and stable measurement.
3. Contactless real-time temperature display is realized since the highly sensitive far IR temperature probe is used for monitoring the bed surface temperature.
4. Sound-light alarm function makes it easy to detect power outage, temperature deviation, sensor failure and overheat.
5. The timer of this infant radiant heater enables accumulative timing and precisely records the baby's therapy time.
6. Horizontal ±90° rotation is achievable for the radiant head.
7. The electric bed enables ±10° adjustment in tilting angle, the organic glass baffles of which are collapsible.
8. An X-ray cassette tray is fitted below the bed of this radiant heating device.
9. This infant radiant warmer is capable of electric lifting, which largely facilitates the operation of medical workers.
10. The stand column made from alloy profile is artistic and sturdy.

Technical Parameters
1. Power supply: 110/220V, 60/50Hz
2. Input power: ≤1000VA
3. Normal working conditions:
a. Ambient temperature: 18℃-30℃
b. Relative humidity: 30%-75%
c. Atmospheric pressure range: 700-1060HPa
d. Air velocity: <0.3m/s
4. Temperature control range: 32℃-38℃
5. Temperature control accuracy: ≤0.5℃
6. Warning function:
a. Overheat: 39℃
b. Secondary heat cutoff: 40℃ (heating source cutoff and sound-light alarm)
c. Sensor: Under the circumstances of open circuit and short circuit, heating source cutoff and sound-light alarm are available for the skin and bed temperature sensors. Under the same circumstances, only sound-light alarm is achievable for the room temperature sensor.
d. Power supply: Sound-light alarm will work in case that the power of the infant radiant warmer is failed.
7. Bed temperature uniformity: <2℃
8. Sensor accuracy for skin temperature: ≤0.3℃
9. Sensor accuracy for bed temperature: ≤0.4℃
10. Sensor accuracy for room temperature: ≤0.3℃
11. Heating time: ≤30 minutes
12. Lifting range: 0-20cm
13. Bed inclination angle: ±10°
14. Timing range: ≤24h
15. Rotation scope of the radiation source: ±90°
16. Bed dimension: 64cm×74cm
17. Overall dimension: 70cm×110cm×180cm (when the lifting mechanism is not in use)
18. Maximum bearing capacity of castors:
Single castor≤200kg, four castors≤800kg

Optional Configuration
We provide the following optional configurations for this radiant neonatal rescue unit:
Low-pressure aspirator, oxygen equipment, phototherapy unit

Transportation and Storage Conditions
This infant radiant warmer should be transported or stored under the conditions as follows:
1. Ambient temperature: -40℃- 55℃
2. Relative humidity: ≤95% RH
3. Atmospheric pressure range: 500-1060HPa

Packaging
1. Packaging size: 114cm×94cm×104cm
2. Overall Weight: ≤150kg