Gas Insulated Switchgear Parts

Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Gas Insulated Switchgear Parts
Request a Quote

Mingde Electrical has been exerting great efforts to be a best supplier and provided advantageous gas insulated switchgear parts to customers around the world. With the strong supports of our reliable products, our customers can assemble GIS by themselves in different area.

Apart from quality gas insulated switchgear parts, Mingde also helps our customers to understand the manufacture process of our products and has established several advanced production lines according to the real production requirem

MGFJ-001

New Style GIS Three-position Load Switch's Mechanism MGFJ-001

Technical Parameters of the GIS Three-position Load Switch's Mechanism
1. Matching with the new GIS load switch;
2. Its output and manual operation share the same shaft;
output torque >60 N•m; output angle: ±95°;
3. Accurate open position orientation;
rated voltage of the motor: AC/DC, 220/110/48/24;
motor power: 65W.

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: this high voltage circuit part could be only be installed in a place where there is no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGDJ-002

New Style GIS Circuit Breaker's Mechanism MGDJ-002

Technical Parameters of the GIS Circuit Breaker's Mechanism MGDJ-002
1. Matching with the new GIS circuit breaker;
2. Its output and manual operation share the same shaft;
output torque >60 N•m; output angle: ±95°;
3. Accurate open position orientation;
rated voltage of the motor: AC/DC, 220/110/48/24;
motor power: 65W.

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: this gas insulated switchgear part could be only be installed in a place where there is no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGFJ-003

New Style GIS Three-position Load Switch's Mechanism MGFJ-003

Technical Parameters of GIS Three-position Load Switch's Mechanism MGFJ-003
1. Matching with the new GIS load switch and outgoing switchgear;
2. Its output and manual operation share the same shaft;
output torque >60 N•m; output angle: ±95°;
3. Accurate open position orientation;
rated voltage of the motor: AC/DC, 220/110/48/24;
motor power: 65W.

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGF-004

New Style GIS Three-position Load Switch's Mechanism MGF-004

Technical Parameters of the New Style GIS Three-position Load Switch's Mechanism MGF-004

NO. ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA630
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes5000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGF-005

New Style GIS Three-position Load Switch's Mechanism MGF-005

Technical Parameter of the GIS Three-position Load Switch's Mechanism MGF-005

NO. ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA1250
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes5000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MDG-006

New Style GIS Three-position Load Switch's Mechanism MDG-006

Technical Parameters of the GIS Three-position Load Switch's Mechanism MDG-006

NO.ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA630
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes6000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MDG-007

GIS Three-position Load Switch's Mechanism MDG-007

Technical Parameters of the GIS Three-position Load Switch's Mechanism MDG-007

NO. ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA1250
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes6000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGKJ-008

GIS Three-position Load Switch's Mechanism MGKJ-008

Technical Parameters of the GIS Three-position Load Switch's Mechanism MGKJ-008
1. Matching with ABB GIS three-position inlet switch and switches manufactured by our factory;
2. Its output and manual operation share the same shaft;
output torque >80 N•m; output angle: ±95°;
3. Accurate open position orientation;

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGKJ-009

GIS Three-position Inlet Switch's Motor-operated Mechanism MGKJ-009

Technical Parameters of the GIS Three-position Inlet Switch's Motor-operated Mechanism MGKJ-009
1. Matching with ABB GIS three-position inlet switch and switches manufactured by our factory;
2. Its output and manual operation share the same shaft;
output torque >80 N•m; output angle: ±95°;
3. Accurate open position orientation;
rated voltage of the motor: AC/DC, 220/110/48/24;
motor power: 65W.

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGKJ-010

GIS Three-position Outlet Switch's Manually-operated Mechanism MGKJ-010

Technical Parameters of the GIS Three-position Outlet Switch's Manually-operated Mechanism MGKJ-010
1. Matching with ABB GIS three-position inlet switch and switches manufactured by our factory;
2. Its output and manual operation share the same shaft;
output torque >80 N•m; output angle: ±95°;
3. Accurate open position orientation;

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGKJ-011

GIS Three-position Outlet Switch's Motor-operated Mechanism MGKJ-011

Technical Parameters of GIS Three-position Outlet Switch's Motor-operated Mechanism MGKJ-011
1. Matching with ABB GIS three-position inlet switch and switches manufactured by our factory;
2. Its output and manual operation share the same shaft;
output torque >80 N•m; output angle: ±95°;
3. Accurate open position orientation;

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGDJ-012

GIS Circuit Breaker's Manually-operated Mechanism MGDJ-012

Technical Parameters of the GIS Circuit Breaker's Manually-operated Mechanism MGDJ-012
1. Matching with ABB GIS circuit breaker and switches manufactured by our factory;
2. Its output and manual operation share the same shaft;
output torque >80 N•m; output angle: ±95°;
3. Accurate open position orientation;

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGDJ-013

GIS Circuit Breaker's Motor-operated Mechanism MGDJ-013

Technical Parameters of the GIS Circuit Breaker's Motor-operated Mechanism MGDJ-013
1. Matching with ABB GIS circuit breaker and switches manufactured by our factory;
2. Its output and manual operation share the same shaft;
output torque >80 N•m; output angle: ±95°;
3. Accurate open position orientation;

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: this high voltage circuit part could be only be installed in a place where is no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGDJ-014

GIS Circuit Breaker's Manual Mechanism and Disconnector's Manual Mechanism MGDJ-014

Technical Parameters of the GIS Circuit Breaker's Manually Mechanism and Disconnector's Manual Mechanism MGDJ-014
1. Matching with ABB GIS circuit breaker, disconnector and those manufactured by our factory;
2. Its output and manual operation share the same shaft;
output torque >80 N•m; output angle: ±95°;
3. Accurate open position orientation;

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: this gas insulated switchgear part could be only be installed in a place where no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGDJ-015

GIS Circuit Breaker's Motor Mechanism and Disconnector's Motor Mechanism MGDJ-015

Technical Parameters of the GIS Circuit Breaker's Motor Mechanism and Disconnector's Motor Mechanism MGDJ-015
1. Matching with ABB GIS circuit breaker, disconnector and those manufactured by our factory;
2. Its output and manual operation share the same shaft;
output torque >80 N•m; output angle: ±95°;
3. Accurate open position orientation;

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: this high voltage circuit part could be only be installed in a place where is no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGJD-016

GIS Outlet Below Earthing Switch MGJD-016

Technical Parameters of the GIS Outlet Below Earthing Switch MGJD-016

NO. ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA200
3Pole center distancemm107
4Theoretic mechanical lifetimes3000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: this gas insulated switchgear accessory could be only be installed in a place where is no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGF-017

GIS Three-position Load Switch (with earthing switch) MGF-017

Technical Parameters of the GIS Three-position Load Switch (with earthing switch) MGF-017

NO. ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA630
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes3000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: this gas insulated switchgear accessory could be only be installed in a place where is no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGF-018

GIS Three-position Load Switch (without earthing switch) MGF-018

Technical Parameters of the GIS Three-position Load Switch (without earthing switch) MGF-018

NO. ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA630
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes3000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGD-019

GIS Circuit Breaker (without disconnector, without earthing switch) MGD-019

Technical Parameters of the GIS Circuit Breaker (without disconnector, without earthing switch) MGD-019

NO.ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA630
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes5000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGD-020

GIS Circuit Breaker (with disconnector, without earthing switch) MGD-020

Technical Parameters of the GIS Circuit Breaker (with disconnector, without earthing switch) MGD-020

NO. ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA630
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes5000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGD-021

GIS Circuit Breaker (with disconnector, with earthing) MGD-021

Technical Parameters of the GIS Circuit Breaker (with disconnector, with earthing) MGD-021

NO.ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA630
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes5000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.

MGD-022

GIS Disconnector (without earthing switch) MGD-022

Technical Parameters of the GIS Disconnector (without earthing switch) MGD-022

NO. ItemUnitTechnical data
1Rated frequencyHz50
2Rated currentA630
3Rated short time withstand currentkA20/25
4Rated peak withstand currentkA63
5Rated duration of short circuits2
6Rated short circuit making currentkA63
7Theoretic operationtimes5000

Ambient Conditions
1. altitude: under 2000m;
earthquake magnitude: no more than magnitude 8;
2. air temperature: -30℃ to 40℃;
3. Relative humidity: under 95%(daily average), 90%(month average);
4. Installation conditions: this high voltage circuit part could be only be installed in a place where there is no frequent serious vibration, water vapor, gas, chemical corrosive deposit, salt mist, dust, fire nor explosive materials which substantially undermine the mechanism's performance.