SDEC Powered Diesel Generators

SDEC Powered Diesel Generators
SDEC Powered Diesel Generators
Request a Quote

Our diesel generator sets are equipped with SDEC engines and advanced emission control technologies such as EGR (exhaust gas recirculation) and SCR (selective catalytic reduction). Meeting China III and, for select models, China IV emission standards, they are engineered to balance reliable power delivery with reduced environmental impact. Suitable for a variety of industrial, commercial, and backup power needs, they provide a reliable electricity source while supporting cleaner, more sustainable operations.

Frequency 50Hz 60Hz
Prime Power 10-1250kVA (8-1000kW) 20-825kVA (16-660kW)
Standby Power 14-1375kVA (8.8-1100kW) 22-908kVA (17.6-726kW)
Fuel Consumption 3.0-286L/h 6.1-182.8L/h
Displacement 1.1-35.1L 2.3-25.2L
Technical Specifications
50Hz Diesel Generator Sets
Genset Model Prime Power Standby Power Engine Model Fuel Consumption Cylinder Displacement
kVA kW kVA kW L/h L
CDS11 10 8 8.8 3Z1.1-G42 3.0 3L 1.1
CDS14 12.5 10 14 11 3ZT1.1-G42 3.8 3L 1.1
CDS17 15 12 16 13 4Z2.3-G11 4.7 4L 2.3
CDS18 16 13 18 14 3Z1.1-G41 5.1 4L 1.1
CDS23 20 16 23 18 4Z2.7-G11 5.9 4L 2.7
CDS28 25 20 28 22 4Z3.0-G11 7.4 4L 3.0
CDS34 31 25 34 27 4ZT3.2-G11 10.1 4L 3.2
CDS41 37 30 41 33 4Z3.2-G41 9.7 4L 3.2
CDS44 40 32 44 35 4Z3.2-G11 8.6 4L 3.2
CDS56 50 40 56 45 4ZT3.5-G21 12.3 4L 3.5
CDS69 63 50 69 55 4ZT4.1-G21 15.6 4L 4.1
CDS75 69 55 75 60 4ZTAA4.1-G21 16.2 4L 4.1
CDS83 75 60 83 66 4ZTAA3.5-G31 19.1 4L 3.5
CDS88 80 64 88 70 SC4H115D2 18.6 4L 4.3
CDS113 105 84 113 90 SC4H140D2 23.0 4L 4.3
CDS125 115 92 125 100 SC4H160D2 25.1 4L 4.3
CDS138 125 100 138 110 4HTAA4.3-G22 28.3 4L 4.3
CDS150 138 110 150 120 6HTAA6.5-G21 30.5 6L 6.5
CDS188 169 35 188 150 6HTAA6.5-G35 35.9 6L 6.5
CDS206 188 150 206 165 SC7H250D2 40.1 6L 6.4
CDS225 200 160 225 180 SC8D280D2 44.9 6L 8.3
CDS250 225 180 250 200 SC9D310D2 50.4 6L 8.8
CDS275 250 200 275 220 6DTAA8.9-G23 55.1 6L 8.8
CDS313 275 220 313 250 SC10E380D2 60.9 6L 10.8
CDS350 313 250 350 280 SC13G420D2 68.9 6L 12.9
CDS375 350 280 375 300 SC12E460D2 73.3 6L 11.8
CDS400 363 290 400 320 SC12E480D2 77.2 6L 11.8
CDS413 375 300 413 330 6ETAA12.8-G22 88.4 6L 12.8
CDS450 400 320 450 360 SC13E550D2 87.9 6L 12.8
CDS500 450 360 500 400 6ETAA12.8-G31 95.8 6L 12.8
CDS550 500 400 550 440 6ETAA12.8-G310 107.5 6L 12.8
CDS563-1 500 400 563 450 6KTAA25-G311 109.0 6L 25.2
CDS625 563 450 625 500 6KTAA25-G310 122.0 6L 25.2
CDS688 625 500 688 550 6KTAA25-G39 133.5 6L 25.2
CDS750 688 550 750 600 6KTAA25-G38 143.1 6L 25.2
CDS825 750 600 825 660 6KTAA25-G32 161.5 6L 25.2
CDS900 825 660 900 720 6KTAA25-G31 172.5 6L 25.2
CDS1000 900 720 1000 800 6KTAA25-G320 197.1 6L 25.2
CDS1100 1000 800 1100 880 6KTAA25-G321 212.8 6L 25.2
CDS1250 1125 900 1250 1000 6WTAA35-G310 259.2 6L 35.1
CDS1375 1250 1000 1375 1100 6WTAA35-G311 286.0 6L 35.1
60Hz Diesel Generator Sets
Genset Model Prime Power Standby Power Engine Model Fuel Consumption Cylinder Displacement
kVA kW kVA kW L/h L
CDS22 20 16 22 17.6 4Z2.3-G12 6.1 4L 2.3
CDS22 20 16 22 17.6 4Z2.3-G21 6.1 4L 2.3
CDS28 25 20 27.5 22 4Z2.7-G12 7.1 4L 2.7
CDS28 25 20 27.5 22 4Z2.7-G21 7.1 4L 2.7
CDS33 30 24 33 41 4Z3.0-G12 8.4 4L 3.0
CDS33 30 24 33 41 4Z3.0-G21 8.4 4L 3.0
CDS41 37.5 30 41 33 4Z3.2-G12 10.4 4L 3.2
CDS41 37.5 30 41 33 4ZT3.2-G12 10.4 4L 3.2
CDS47 42.5 34 47 37 4ZT3.2-G21 11.1 4L 3.2
CDS47 42.5 34 47 37 4ZT3.2-G21 12.4 4L 3.2
CDS66 60 48 66 53 4ZT3.5-G21 15.7 4L 3.5
CDS69 63 50 69 55 4HT4.3-G21 15.8 4L 4.3
CDS75 69 55 75 60 4HT4.3-G22 17.0 4L 4.3
CDS77 70 56 77 62 4ZT4.1-G21 19.1 4L 4.1
CDS83 75 60 83 66 4ZTAA4.1-G21 20.1 4L 4.1
CDS88 80 64 88 70 4ZTAA4.1-G31 20.5 4L 4.1
CDS100 90 72 100 80 4HT4.3-G23 21.6 4L 4.3
CDS125 113 90 125 100 4HTAA4.3-G21 23.0 4L 4.3
CDS138 125 100 138 110 4HTAA4.3-G23 28.8 4L 4.3
CDS138 125 100 138 110 4HTAA4.3-G22 27.5 4L 4.3
CDS165 150 120 165 132 6HTAA6.5-G21 28.7 6L 6.5
CDS175 160 128 175 140 6HTAA6.5-G22 34.4 6L 6.5
CDS225 206 165 225 180 6HTAA6.5-G23 37.6 6L 6.5
CDS250 225 180 250 200 6DTAA8.9-G21 42.0 6L 8.9
CDS275 250 200 275 220 6DTAA8.9-G24 54.2 6L 8.9
CDS300 275 220 300 240 6DTAA8.9-G23 59.4 6L 8.9
CDS375 350 280 375 300 6ETAA11.8-G22 73.7 6L 11.8
CDS375 350 280 375 300 6ETAA11.8-G21 71.6 6L 11.8
CDS413 375 300 413 330 6ETAA12.8-G22 88.4 6L 12.8
CDS440 400 320 440 352 6ETAA12.8-G21 88.4 6L 12.8
CDS550 500 400 550 440 6ETAA12.8-G310.1 108.5 6L 12.8
CDS619 563 450 619 495 6KTAA25-G311 1,274 6L 25.2
CDS688 625 500 688 550 6KTAA25-G310 137.5 6L 25.2
CDS770 700 560 770 616 6KTAA25-G39 149.9 6L 25.2
CDS770 700 560 770 616 6KTAA25-G38 149.9 6L 25.2
CDS825 750 600 825 660 6KTAA25-G32.1 171.7 6L 25.2
CDS908 825 660 908 726 6KTAA25-G31.1 182.8 6L 25.2

All of our gensets come standard with an epoxy-coated enclosure and IP55 protection rating. A copper-nickel alloy radiator can be selected for enhanced corrosion resistance, and weekly freshwater rinsing is recommended to remove salt deposits.

For light diesel applications, we recommend China’s national standard No. 0 or -10 diesel with sulfur content ≤10 ppm. Inferior fuel should be strictly avoided. Heavy fuel oil is permitted only for specific marine or industrial models (such as the SC9DF series) and must be preheated to 90-120°C before use.

Optional ComAp Cloud or SmartGen HGM systems allow operators to view real-time data and receive fault alerts via mobile app, enabling efficient monitoring without being on-site.