Anesthesia Machine
Our S6100 anesthesia machine, also called anesthetic machine is designed with safety in mind. Combining proven ventilation technology, the anesthesia system is primarily used for inhalation anesthesia, breathing control, as well as monitoring and display of the patient's ventilation parameters.
Features
1. Electric control and pneumatic control methods;
2. With a variety of alarm, presentation and protection functions;
3. Backup battery is available to enable the medical equipment to continue to work after power failure;
4. 10.4" colorful LCD display shows patient's ventilation parameters, alarm information, and the graphical display;
5. For both adult and pediatric application;
6. Volume control, pressure limit and work in a variety of ways;
7. Anesthetics vaporizer with temperature and flow compensation and zero self-locking function is employed;
8. O2 and N2O flow meter has the linkage, ensuring the O2 concentration is up to 25% or more;
9. The anesthesia machine comes with an alarm for insufficient pressure of O2 and a N2O truncation protection function;
10. Equipped with an exhausted gas transmission and collection system
Air source | O2, N2O, air |
Air pressure | 280 kPa~ 600 kPa |
Power supply | 100-240V |
Frequency | 50 /60HZ |
Input power | 80 VA |
Ventilation mode
IPPV
A/C
PCV
SIMV
SIGH
MANU
Flow meter | O2 | 0.1 ~ 10 L/min |
N2O | 0.1 ~ 10 L/min | |
AIR | 0.1 ~ 10 L/min | |
Oxygen flush | 35 L /min ~ 75 L/min | |
Tidal volume (VT) | 0 Ml~1500 mL | |
Including | For adult: 250 mL ~ 1500 mL | |
For children: 0 mL ~ 300 mL | ||
MV | For adult: ≥ 18 L/min | |
For children: ≥ 10 L/min | ||
Frequency | 1bpm~100 bpm (SIMV mode: 1 bpm ~40 bpm Except SIMV mode: 4 bpm~40 bpm for adult; 20bpm~100 bpm for children) | |
I/E | 4:1~1:8 | |
PEEP | 0 cmH2O ~ 30 cmH2O | |
Stress triggering sensitivity ( PTr ) | - 20 cmH2O ~ 0 cmH2O ( Based on PEEP ) | |
Flow trigger sensitivity ( FTr ) | closed , 0.5 L/min ~ 30 L/min | |
Pressure control ( Pc ) | 5 cmH2O ~ 60 cmH2O | |
Breathless time (aspiratory breathless, breath at the end of the platform) ( TIP ) | 0 ~ 6s( ≤ 50 % Aspiratory time) | |
SIGH | 1/100 ~ 5/100 | |
Apnea Ventilation OFF | 5 s ~ 60 s | |
Apnea Ventilation | 20 cmH2O ~ 100 cmH2O |
Frequency | 0 /min ~ 100 /min |
Tidal volume (Vt) | 0 mL ~ 2000 mL |
MV | 0 L /min ~ 100 L/min |
Airway pressure | 0 cmH2O ~ 100 cmH2O |
Patients with dynamic lung compliance | 1mL/cmH2O ~ 1000 mL/cmH2O |
Concentration of inspired oxygen | 15 %~100 % |
Graphical Display:
P-Tl
F-Tl
P-V loopl