Perkins Powered Diesel Generators

Perkins Powered Diesel Generators
Perkins Powered Diesel Generators
Perkins Powered Diesel Generators
Request a Quote
Diesel Powered Generator Set Manufacturer

Our Perkins powered diesel generator sets are built with genuine Perkins engines, a brand that has delivered dependable generator drive engines for over 85 years. Known for their ability to operate in harsh environments, under strenuous conditions, or emergency use, Perkins engines are trusted worldwide for their durability and consistent power output. Featuring noise-reducing technology and meeting EU Stage III emission standards, our Perkins-powered generators operate quietly while ensuring environmental compliance. With a power range from 15 kVA to 2500 kVA and ISO 9001 certification, these generator sets are perfectly suited for large manufacturing plants, marine applications, and critical emergency power supply, providing reliable energy when it’s needed most.

Applications
  • Industrial: Widely used across industrial sectors, Perkins powered generators deliver stable and reliable power to keep machinery running smoothly and production lines operating without interruption
  • Agricultural: Compact yet powerful Perkins engines are ideal for small agricultural machines such as hand tractors and mowers, providing dependable performance for a variety of farming tasks
  • Commercial: Ideal for commercial facilities like shopping malls and hotels, ensuring a continuous power supply that keeps daily operations running efficiently
Main Components

A Perkins powered diesel generator set is built with key components including the engine, alternator, radiator, enclosure, and control panel, each designed and assembled to ensure reliable power generation and long-term durability.

    1. Engine Delivers strong power with stable performance and efficient fuel consumption
    1. Alternator

      Features a rotating field, brushless, single-bearing design with Class H insulation and IP23 protection, sealed maintenance-free bearings, and three-phase four-wire output

    1. Radiator

      Provides high-efficiency cooling to extend engine life and enhance performance, offering excellent corrosion and aging resistance with easy maintenance.

    1. Control panel

      Weather-resistant and fully automated, capable of monitoring key operating parameters such as temperature, speed, and oil pressure. Custom control panels can be designed to meet specific application requirements.

Optional Configurations
    1. Additional fuel tank

      Designed as an optional unit that can be integrated to save cost and space while providing greater fuel capacity and higher-pressure tolerance for extended runtime.

    1. Automatic Transfer Switch (ATS)

      Detects power outages and automatically switches to backup power within seconds, keeping your equipment running and protecting against downtime or data loss. Equipped with overcurrent and short-circuit protection, the ATS reduces system costs compared to dual breaker setups and improves switching reliability with mechanical and electrical interlocks.

    1. Custom soundproof enclosure

      Significantly reduces operational noise to meet environmental noise regulations. Built with safety in mind, including inspection windows and service doors for convenient monitoring and maintenance. Compatible with a wide range of generator models, helping enhance workplace efficiency and stay compliant with noise regulations.

Available Perkins Diesel Generator Models
      • Frequency/Speed: 50Hz/1500rpm
        Prime Power: 30-250kVA (24-200kW)
        Standby Power: 32.5-275kVA (26-220kW)
        Governor: Mechanical/ECM
        Emissions Level: N/A
      • Frequency/Speed: 60Hz/1800rpm
        Prime Power: 35-225kVA (28-180kW)
        Standby Power: 38.75-250kVA (31-200kW)
        Governor: Mechanical/ECM
        Emissions Level: N/A
      • Frequency/Speed: 50Hz/1500rpm
        Prime Power: 257.5-650kVA (206-520kW)
        Standby Power: 282.5-700kVA (226-560kW)
        Governor: ECM
        Emissions Level: N/A, EU Stage II
      • Frequency/Speed: 60Hz/1800rpm
        Prime Power: 290-625kVA (232-500kW)
        Standby Power: 320-687.5kVA (256-550kW)
        Governor: ECM
        Emissions Level: N/A, EU Stage II
      • Frequency/Speed: 50Hz/1500rpm
        Prime Power: 13-250kVA (10.4-200kW)
        Standby Power: 14.5-275kVA (11.6-220kW)
        Governor: Mechanical/Electric
        Emissions Level: N/A, EU Stage II, EU Stage IIIA
      • Frequency/Speed: 60Hz/1800rpm
        Prime Power: 11.25-225kVA (9-180kW)
        Standby Power: 12.38-250kVA (9.9-200kW)
        Governor: Mechanical/Electric
        Emissions Level: N/A, EU Stage II, EU Stage IIIA
      • Frequency/Speed: 50Hz/1500rpm
        Prime Power: 30-2250kVA (24-1800kW)
        Standby Power: 32.5-2500kVA (26-2000kW)
        Governor: Mechanical/Electric
        Emissions Level: N/A
      • Frequency/Speed: 60Hz/1800rpm
        Prime Power: 35-1687.5kVA (28-1350kW)
        Standby Power: 38.75-1875kVA (31-1500kW)
        Governor: Mechanical/Electric
        Emissions Level: N/A

We ensure quality through strict raw material inspections, close monitoring throughout the production process, and comprehensive testing of every unit before delivery.

It’s recommended to run the generator at least once a month for about 20 minutes (10 minutes for INV2000 models) under normal operating temperature and load as part of routine maintenance.