HFP Series Concealed Ceiling Mounted Fan Coil Unit

HFP Series Concealed Ceiling Mounted Fan Coil Unit
HFP Series Concealed Ceiling Mounted Fan Coil Unit
Request a Quote
Air volume340÷2490m3/h
Cooling capacity 2.16÷13.1kW

Features of Concealed Ceiling Mounted Fan Coil Unit
1. Smaller volume. Of a laconic structure, this concealed ceiling mounted fan coil unit is only as thick as 230mm. Meanwhile, it is easy to install the unit and conduct the piping work and wire connection work;
2. High efficiency. This concealed ceiling mounted fan coil unit is manufactured with advanced expansion lock techniques which ensures the close contact between cooper tube and aluminum fin both of which are the indispensable parts of the heat exchanger. Therefore, the later enjoys quite highly efficient heat transferring performance;
3. Low noise. Thanks to its low noise motor fan, scientific airflow design and sound-absorbing and insulation materials, this commercial fan coil apparatus could operate with quite low noise which is lower than the national standard of 1-3Db(A). The standard static pressure is 12Pa and the high static pressure 30Pa;
4. Low energy consumption. The three-speed motor fan of this concealed mounted ari conditioning unit would effectively cooperate with the heat exchanger and enable users to adjust the air volume, helping reducing energy consumption.

Technical Advantages of Concealed Ceiling Mounted Fan Coil Unit
Based on our years' R&D and manufacturing experience, HUICON has provided many reliable commercial and civilian fan coil units which are made with advanced techniques both at home and abroad. Of excellent cooling performances, our fan coil unit, a reliable terminal device of central air condition system, enjoy rich types and could be applied in various occasions such as apartment, hotel, hospital, office building and shopping mall.

Model3-row coil 1-row coil(4-row coil)
HEP-34HEP-51HEP-68HEP-85HEP-102HEP-136HEP-170HEP-204HEP-238
Nominal air volume(m3/h)34051068085010201360170020402380
Nominal cooling capacity (W)22933180392050065991784196521145413423
Nominal heating capacity(W)159622652887348241465434635477519034
fanTypeForward curved centrifugal fans with double inlets and small blades
quantity122223444
Motorpower220V~50Hz
Input powerCommon type3651617596133151188227
High-pressure type43587186107155173211253
Waterflow(l/min)6.57/2.289.1/3.2411.24/4.1314.35/4.9817.17/5.9422.4/7.7827.66/9.132.8/11.139.44/12.94
Cold water resistance(kPa)2.365.5110.4317.0625.258.5313.4120.7229.86
Hot water resistance(kPa)1.794.197.9310.0719.26.4910.215.7522.7
Noise dB(A)Common type373941434546485052
High pressure type404244464748505254
Heat exchangercomponentsCooper tube, aluminum fin and mechanical expansion pipe
Maximum operating pressure1.6Mpa
PipingCooling: water inlet pipe: Rp3/4" condensate pipe: R3/4; Heating: water inlet pipe: 3/8"
Weight(kg)WA15.51820232532363855
WAP1,218.52325283140465069

Please note that
1. The noise data are measured as the unit is placed in an anechoic chamber and the measuring device keeps 1 meter away from the unit;
2. The standard working condition is:
cooling mode: DB/WB: 27℃/19 ℃, cooled water inlet: 7 ℃, temperature difference between the water inlet and outlet: 5 ℃;
heating mode: DB: 21 ℃, heated water inlet temperature: 60 ℃;
3. The static pressure of standard unit is 12Pa and that of the high static pressure type is 30Pa;
4. Data in the above table is measured when the fan is set with high air volume(the medium and low air volumes are respectively 80% and 60% of that of the high air volume).

Model3-row coil
HEP-34HEP-51HEP-68HEP-85HEP-102HEP-136HEP-170HEP-204HEP-238
Nominal air volume (m3/h)34051068085010201360170020402380
Nominal cooling capacity21653000373348145652754094201123013100
Nominal heating capacity3456468759737472888511243141201722619360
FantypeForward curved centrifugal fans with double inlets and small blades
Quantity122223444
MotorPower220V~50Hz
Input powerCommon type3340627695134152189228
High pressure type40507287106144174209253
Waterflow(l/min)6.28.610.713.816.222.227.833.138.6
Water drop(kPa )5.6510.0114.823.230.781623.6732.1442.21
Noise dB(A)Common type373941434546485052
High pressure type404244464748505254
Heat exchanger componentsCooper tube, aluminum fin and mechanical expansion pipe
Maximum operation pressure1.6Mpa
PipingCooling: water inlet pipe: Rp3/4" condensate pipe: R3/4.
Weight(kg)WA151719222430343653
WAP1,2182224273038444867
WM313336383855627277
LA182123242637414860
LM293133353852586985
KBM343639414452545969
KQM/30394646515959/

Please note that
1. The noise data are measured as the unit is placed in an anechoic chamber and the measuring device keeps 1 meter away from the unit;
2. The standard working condition is:
cooling mode: DB/WB: 27℃/19 ℃, cooled water inlet: 7 ℃, temperature difference between the water inlet and outlet: 5 ℃;
heating mode: DB: 21 ℃, heated water inlet temperature: 60 ℃;
3. The static pressure of standard unit is 12Pa and that of the high static pressure type is 30Pa;
4. Data in the above table is measured when the fan is set with high air volume(the medium and low air volumes are respectively 80% and 60% of that of the high air volume).

Model2-row coil
HEP-34HEP-51HEP-68HEP-85HEP-102HEP-136HEP-170HEP-204HEP-238
Nominal air volume (m3/h)36051072090010701430179021402490
Nominal cooling capacity(W)18002700360045005400720090001080012600
Nominal heating capacity(W)3150425056406800809010880135901665018900
FanTypeForward curved centrifugal fans with double inlets and small blades
Quantity122223444
Motor Power220V~50Hz
Input powerCommon type3752627696134152189228
High pressure type44597287108156174212253
Waterflow(l/min)5.3810.313.315.921.226.631.937.2
Water drop(kPa)6.115.628.7425730.844.5259.872.5
Noise dB(A)Common type373941434546485052
High static pressure type404244464748505254
Heat exchangerComponentCooper tube, aluminum fin and mechanical expansion pipe
Maximum operation pressure 1.6Mpa
Piping Cooling: water inlet pipe: Rp3/4", outlet pipe: Rp3/4", condensate pipe: R3/4;
Weight (kg)WA141618212328323451
WAP1,2172123262936424665
WM303235374053607075
LA172022232535394658
LM283032343750566783

Please note that
1. The noise data are measured as the unit is placed in an anechoic chamber and the measuring device keeps 1 meter away from the unit;
2. The standard working condition is:
cooling mode: DB/WB: 27℃/19 ℃, cooled water inlet: 7 ℃, temperature difference between the water inlet and outlet: 5 ℃;
heating mode: DB: 21 ℃, heated water inlet temperature: 60 ℃;
3. The static pressure of standard unit is 12Pa and that of the high static pressure type is 30Pa;
4. Data in the above table is measured when the fan is set with high air volume(the medium and low air volumes are respectively 80% and 60% of that of the high air volume).